Type
Cooling capacity outlet temperature
Pump
Vent.
Com-pressor
Pump
Con-tainer
Weight*
Connec-tion
Air Volume
Noise
Dimensions
mm
Drawing No.
WRK
20°C/kW
10°C/kW
kW
kW
kW
l/min
bar
Ltr.
kg
m3/min
Db(A)
B
T
H
Size No.
03
0,84
0,7
0,07
-
0,43
4
1,5
6
30
G3/8"
6
68
570
400
315
3833-3833
04
1,30
0,9
0,07
-
0,73
4
1,5
6
30
G3/8"
6
68
570
400
315
3833-3833
05
2,30
1,6
0,33
0,13
0,93
12
3,0
16
50
G1/2"
13
70
400
400
860
3924-3924
06
2,47
1,72
0,33
0,07
1,24
12
3,0
16
84
R1/2"
16
70
580
580
840
1492-1166
08
4,50
3,6
0,33
0,07
1,70
12
3,0
40
95
R1/2"
18
71
580
580
840
1492-1166
10
6,35
5,15
0,76
0,3
2,07
20
4,1
40
105
R3/4"
45
71
680
580
1070
1257-1257
20
7,65
5,80
0,55
0,3
2,44
15
3,1
70
105
R3/4"
60
73
680
680
1070
1493-1167
30
10,44
8,12
0,55
0,3
3,42
23
2,9
70
132
R3/4"
60
73
680
680
1070
1493-1167
40
12,76
10,44
0,55
0,4
4,25
30
2,8
120
155
R3/4"
66
75
900
680
1140
1494-1311
50
17,40
13,92
0,55
0,4
5,60
40
2,7
120
160
R3/4"
66
75
900
680
1140
1494-1311
58
22,50
18,00
0,55
0,57
6,35
45
2,6
120
200
R3/4"
80
75
950
800
1600
4052-1331
60
25,52
20,88
0,55
2x0,4
7,8
50
2,2
180
270
R1"
105
77
1400
900
1280
4053-1307
70
33,64
27,84
1,10
2x0,4
11,0
60
4,6
180
320
R1"
105
77
1400
900
1280
4053-1307
80
38,00
31,00
1,10
2x0,57
11,0
70
3,8
300
605
R1 1/2"
180
78
2000
800
1600
4054-1348
90
43,50
35,70
1,65
2x0,57
12,6
100
3,5
300
660
R1 1/2"
180
78
2000
800
1600
4054-1348
93
61,00
48,80
2,46
2x3,0
16,0
170
3,3
500
1000
R1 1/2"
420
79
2260
1300
1705
4055-1381
95
75,00
60,50
2,76
2x3,0
20,3
215
3,1
500
1200
DN50
420
79
2260
1300
1705
4055-1381
97
91,00
72,80
3,00
2x3,0
24,1
260
3,8
500
1500
DN50
420
79
2710
1300
2130
4056-1382
100
106,00
85,00
3,00
2x3,0
30,5
285
3,4
1000
1700
DN50
530
79
2710
1300
2130
4056-1382
* applicable to the corresponding basic equipment

Including a fully hermetical cooling agent compressor for the cooling of clean water, glycol mix or emulsion. A powerful water pump (WRK30-100 made of stainless steel), a container and a complete electrical control system are incorporated.

The special evaporator allows preliminary water temperatures of up to approx. 2ºC without anti-freezer. Even complete freezing will not cause any defects or total failure. Avoid excessive expenses for cooling water and complicated installations by using a sophisticated installation system, and use Water Re-Coolers made by BKW instead.

Application


Welding machines, laser-plasma plants, electron microscopes, X-ray tubes, hydraulic systems (indirect), plastics injection moulding machines, cleaning and degreasing systems, air conditioning equipment etc.

A stainless, 300 – 400 – 500 ltr. steel boiler is available as an accessory part for heat recovery applications. It is particularly recommended to equip the Water Re-Cooler with a heat pump condenser. This allows the heating of water to 418 K (45ºC) for a variety of applications at "zero cost". Cold and warm water temperatures can be adjusted individually in a range of 0 to 60ºC (TD 3K) via display thermostats. If the temperatures at the place of your installation drop under 283 K (10ºC), please indicate this in your purchase order.

Data Sheet

PDF data sheet: BKW Water Re-Coolers (230.202)

Share |

Related

Haimer Power Clamp Power Coolers

Haimer Power Clamp Power Coolers
The Power Cooler is a new cooling unit to cool down tool holders. An air stream interspersed with a fine water mist cools down the shrink fit chucks of any shape in record...
Details PDF

 BKW SK Series Electrical Cabinet Coolers

BKW SK Series Electrical Cabinet Coolers

Details

BKW Mini Water Cooler

BKW Mini Water Cooler
The BKW Mini Water Color can be used for many diverse applications. Some examples include welding machinery, Laser-Plasma installations, electron microscopes, X-ray tubes,...
Details PDF

BKW Control Cabinet Coolers

BKW Control Cabinet Coolers
Electronic control systems are prone to malfunctions if exposed to high temperatures. The cooling is often performed by the blowing-in of external air or via indirect air/air...
Details PDF

BKW Heat Exchangers

BKW Heat Exchangers
These cooling systems facilitate the cooling of oils and other media (with BKW equipment even contaminated media). Water is supplied at the front inlet side from the internal...
Details PDF

BKW Immersion Liquid Re-Coolers

BKW Immersion Liquid Re-Coolers
No additional space required thanks to the possibility of positioning the Immersion Re-Cooler onto the oil or liquid container. Large-surface evaporator made of standard steel...
Details PDF

Oswald FQD Asynchronous Motors with Water Cooling

Oswald FQD Asynchronous Motors with Water Cooling
Liquid-cooled OSWALD asynchronous motors and generators series FQD are particularly suitable when heavy demands are placed on a drive system. The motors are designed for wide...
Details PDF

Oswald MF Synchronous Motors

Oswald MF Synchronous Motors
Liquid-cooled OSWALD synchronous motors and generators series M are particularly suitable when heavy demands are placed on a drive system. The motors are designed for wide...
Details PDF

Haimer Power Clamp Shower Coolers

Haimer Power Clamp Shower Coolers
For rapid cooling of tools. Add-on for all shrink fit machines.
- Suitable for all contours
- Drying by rotating air nozzles
- Supplementing existing...
Details PDF